Gas Mass Flow Controller MFC

  • Direct measurement and control of gas mass flow.
  • Equipped with an internal control valve for stabilizing and automatically adjusting the flow rate to the setpoint.
  • Excellent accuracy and repeatability in flow control, even at very low flow rates.
  • Fast response for rapid flow adjustment.
  • The gas type, operating pressure, and temperature must match the model’s calibration range.

Engineering-Led Selection

Genuine Products, Direct Sourcing

×

Phone:

021-66572717
Product Overview

A thermal mass flow controller (MFC) is an advanced device that not only accurately measures the mass flow rate of gases, but also adjusts and controls it.

The device works by transferring heat from a heating element to the gas flow. This enables the MFC to directly calculate the mass flow rate and measure gas mass flow within its specified calibration range.

The main difference between a controller and a thermal flow meter is the controller’s built-in fast, precise control valve. An operator or control system (PLC) can send a reference mass flow rate (Set Point) to the device. The MFC’s control unit then compares the measured flow rate with the reference value and continuously adjusts the control valve position to keep the gas outlet flow rate precisely at the desired value. This capability is highly useful in sensitive, automated processes such as semiconductor equipment, precise gas mixing, chemical reactor systems, and gas chromatography instruments.

Key Features
Measured Variable
Measurement Technology
Fluid Type
Installation Type
Accuracy Class
Output Signal
Power Supply
Process Connection
Portability
Technical Documents
Datasheet 1 document
Videos
Introduction to Low-Flow Mass Flow Meters

Introduction to Low-Flow Mass Flow Meters

Request a Quote
Technical & Commercial RFQ

Submit Your Request in One Place

You can add multiple instruments to one request. The form shows the fields available for each product.

ATA SMART RFQ Engineering Insight, Precision Supply
۱

Contact Information

We will send the quotation response to this contact.

۲

Select and Add a Product

Search for a product or select one from the list to add its form.

Standard specifications will be listed in the quotation. You can request changes after receiving it.

۳

Attachments and Notes

Attach at least one file when choosing Upload RFQ Files Only.

Choose FilesPDF, Word, Excel, image, DWG or DXF — up to 10 MB per file
    ۰ قلم تجهیزAll items and files will share one tracking number.

    Frequently Asked Questions

    In addition to measuring flow, an MFC has a control valve and control circuit. It compares the flow rate with the setpoint and regulates it within its operating range.

    Depending on the model, an analog signal, digital communication, or local control is used. The command type and its scale must be compatible with the PLC or controller.

    No. The valve requires sufficient differential pressure to control flow. The inlet pressure, outlet pressure, and valve capacity must be suitable for the requested flow rate.

    No. The gas type and compatible materials must be specified. Changing the gas may require manufacturer-approved settings or recalibration.

    This should not be assumed without checking the manufacturer’s specifications. Allowable leakage and de-energized behavior must be verified; a separate valve may be required for fail-safe shutoff.

    Fluctuating supply pressure, restrictions in the outlet line, an unsuitable range selection, and control settings are possible causes. Troubleshooting should start with the actual inlet and outlet conditions.