In-line Thermal Mass Flow Meter

  • Direct measurement of gas mass flow.
  • High sensitivity to flow changes at low flow rates.
  • Direct mass measurement within the model’s permissible ranges for gas pressure, temperature, and composition.
  • No moving parts in the flow path and negligible pressure drop.
  • Suitable for large pipes and harsh operating environments, with a wide measurement range.

Engineering-Led Selection

Genuine Products, Direct Sourcing

×

Phone:

021-66572717
Product Overview

Thermal mass flowmeter In-line is a type of flowmeter that directly measures the mass flow of gases, rather than their volumetric flow. These flowmeters are designed for permanent installation in medium- to large-diameter pipelines.

This flowmeter operates based on the amount of thermal energy transferred from a thermal sensor to the surrounding environment by the gas flow. The higher the gas mass flow rate, the more heat is carried away from the sensor, causing its temperature to drop. By measuring the energy required to maintain a constant temperature difference between two sensors—one heated and the other serving as a reference—the flowmeter calculates the gas mass flow rate.

The main advantage of this model is that it measures mass flow directly, typically eliminating the need to separately convert volumetric flow using pressure and temperature. However, the gas type and composition, as well as the calibration pressure and temperature range, must be taken into account.

Common applications for these flowmeters include accurately monitoring and controlling the flow of air, gaseous fuels, process gases, and compressed air in petrochemical plants, power plants, gas treatment facilities, and manufacturing plants.

Key Features
Measured Variable
Measurement Technology
Fluid Type
Installation Type
Display Type
Output Signal
Power Supply
Process Connection
Portability
Technical Documents
Datasheet 1 document
Request a Quote
Technical & Commercial RFQ

Submit Your Request in One Place

You can add multiple instruments to one request. The form shows the fields available for each product.

ATA SMART RFQ Engineering Insight, Precision Supply
۱

Contact Information

We will send the quotation response to this contact.

۲

Select and Add a Product

Search for a product or select one from the list to add its form.

Standard specifications will be listed in the quotation. You can request changes after receiving it.

۳

Attachments and Notes

Attach at least one file when choosing Upload RFQ Files Only.

Choose FilesPDF, Word, Excel, image, DWG or DXF — up to 10 MB per file
    ۰ قلم تجهیزAll items and files will share one tracking number.

    Frequently Asked Questions

    It determines the gas mass flow rate by measuring heat transfer. The standard volumetric display also depends on the reference conditions defined for the device.

    The measurement path and sensor locations are defined within the body. However, installation requires a connection to the pipeline, and sizing and pressure drop must be considered.

    Yes. The gas composition and its thermal properties affect the instrument’s response. The actual gas composition must be compatible with the calibration or valid correction capability of the specific model.

    Models in this range are designed for gas. Applications involving steam, two-phase gas, or liquids require explicit confirmation that the technology and specific model are suitable.

    No. Separate volume-to-mass conversion is generally unnecessary, but the calibration and design pressure and temperature ranges must still be observed.

    Check air quality, entrained water and oil, straight-run requirements, and flow direction. Contamination or condensation on the sensor can affect its response.

    Please provide the gas type and composition, flow rate, pressure, temperature, pipe diameter and connection, output, reference conditions, and inlet gas quality.